Chat with us, powered by LiveChat Residential Electrical Wiring System Paper | All Paper
+1(978)310-4246 credencewriters@gmail.com
  

Aim: To provide the knowledge and design skills to develop a residential electrical wiring system as per regulation standards. Summary of the task Electrical house wiring regulations are necessary to decide the conductor size of cable for 220-240 V electrical supply under different weather conditions. First, it is necessary to understand the significance of power-flow study to fix the voltage-limits from the source to the load point. Then based on 17th wiring regulations/16th IEE wiring regulations/ National wiring regulations, design the ampere carrying capacity of wires used in a house. Further, recommend the safe and cost-effective earthing technique to avoid from electric shock. Furthermore, the report should contain as per the marking scheme given in the attachment name “Appendix and Scheme”. The length of the main body text of the technical report should be between 1500 and 2000 words. Understand the following points to complete the given Electrical Wiring- Design task for the house: 1.Conduct a power-flow study distribution radial network having 04/05 nodes to understand voltage variation from source to load by assuming load data and line data. 2.Collect the electrical load capacity for all appliances of a sample residential house. 3.Calculate the conductor design current (Ib), nominal current (In), perspective current (Iz), short circuit current (Isc) and % voltage drop for 1-phase, AC supply voltage with following parameters: •Standard insulated conductors for group of 2/3/4/5/6 and clip to a surface. •Cable operating under 03 different ambient temperature conditions. •Refer the Appendix (Page-2) to tabulate the results obtained. 4.Sketch and compare the different type of earthing systems used in Oman/Any other opted country for studies and recommend cost effective suitable earthing system. 5.Calculate the earth fault loop impedance for home selected and justify its need. Indicative References: Hadi Saadat, 2009. Power System Analysis, McGraw-Hill, ISBN 16th 0-07-012235-0. International Wire Sales, 2017. https://www.mdm.com/articles/38448-international-wire-sales. [Assessed: 27th Jan 2019]. Teng, J.H., 2000. A Network-Topology-based Three-Phase Load Flow for Distribution Systems. Proc. Natl. Sci. Counc. ROC (A), Vol. 24, No. 4, pp. 259-264. [Online], Available from: https://ejournal.stpi.narl.org.tw/index/items/down… [Accessed: 27th Jan 2019]. Pabla A. S, 2004. Electrical Power Distribution, Mc-Graw-Hill, ISBN 10: 0071447830. IET Wiring Regulations 17th Edition, 2008.BS7671 [Online]. Available from: http://electrical.theiet.org/ https://www.landlord-certificates.co.uk/wp-content… [Accessed: 27th Jan 2019]. Pugha, Archie D, 2012. Electrical Transmission & Substation Structures: Solutions to Building the Grid of Tomorrow. Available from: http://site.ebrary.com/lib/caledonian/detail.action?adv.x=1&docID=10960910&f00=all&f01=subject&p00=electrical+distribution&p01=%22Electric+Power+Distribution%22+OR+%22Electric+Utilities%22+OR+%22Electric+Lines%22. [Accessed: 27th Jan 2019]. *** I’ve uploaded an attachment named “Appendix and Scheme”.
appendix_and_scheme.docx

Unformatted Attachment Preview

Appendix Standards
IEE /IET Wiring
Regulations/
Parameters
Ca
Table 4C1
Cg
Table 4B1
Iz in amps
Iz 
Size in mm2
Table 6A1 and 6A2
Voltage Drop mV/m/A
Table 4D2B
Variation of Ambient Temperature
(www.met.gov.om/opencms/export/sites/default/dgman)
Temperature in…
Temperature
o
Temperature in…..
C
in …. oC
o
C
In
Ci C r C a C g
Scheme
Item
Components
1
2
Abstract & Introduction with citation
Data Selection, Design (Sample Hand Calculations) and implementation steps.
3
Result Analysis, Conclusion and Recommendations
4
Report structure in terms of logic and coherence with proper referencing

Our essay writing service fulfills every request with the highest level of urgency.
attachment

error: Content is protected !!